Solution Description

Energy Conserving Oil Lubricated Rotary Screw Air Compressor

Software: 
Air compressor is common business gear, is the next largest power supply, is also the method air source with multiple makes use of, extensively utilized in mining exploitation, oil drilling, iron and metal metallurgy, electric powered energy, shipbuilding, electronics manufacturing, petroleum chemical industry, mild sector, machinery production, meals and medication, transportation services, shipping and delivery docks, casting coating, car business, aerospace, armed forces engineering, infrastructure and so on fields. 

Functions: Adopt twin rotor/screw air conclude for compression air. 

Benefits of our screw air compressor: 
one. Approved by ISO9001certificate, SGS, CE and and many others…
2. Undertake the most advanced technology and entire world renowned brand name of twin screw major machine creating and manufacturing, no leakage, make certain substantial air discharge and reduced vitality consumption. 
three. Undertake high good quality electric powered motor with CZPT bearing, IP54, convenient maintenance and prolonged use lifestyle. 
four. Undertake entire world famous brand of air consumption filter, oil filter, air and oil separator, understand substantial filtration accuracy, compressed air oil articles beneath 3ppm, get to to intercontinental advanced standard level. 
five. Equip with the most advanced air management method. Undertake air ingestion valve, smart control program and strain sensor merged handle technique, can run by ON and OFF 2 point, stepless air capability handle technique, time-hold off stop and immediately commence system 3 air capacity management techniques, can fulfill distinct customers need. 
six. Intelligent microcomputer control program, Chinese and English language procedure interface, malfunction screen, alarm and equipment quit routinely. 
seven. Adopt large good quality and planet well-known brand name of main factors, like Uk APD oil filter, The united states AMOT temperature managing valve, SCHNEIDER electric powered areas and and so forth., higher effectiveness, reliable and long use daily life. 
eight. Equip with following air compression cooler mix with the air and h2o separator, compact composition and preserve place, steer clear of leakage and enhance the air and drinking water separating effectiveness mostly. 

Parameters of our twin-screw air compressor: 

Product TKL-2F TKL-3F TKL-4F TKL-5F TKL-7F TKL-11F TKL-15F TKL-18F TKL-22F TKL-30F TKL-37F TKL-45F/W TKL-55F/W TKL-75F/W TKL-90F/W
Air displacement/
Exhause strain (m3/min/MPa)
.33/.7 .43/.seven .6/.seven .8/.7 1.23/.7 1.65/.seven two.7/.seven three./.seven 3.6/.seven five.2/.7 6.6/.7 7.8/.7 10.1/10.seven 13.5/.seven 16.3/.7
.33/.eight .4/.eight .fifty five/.8 .7/.eight one.16/.8 one.62/.8 2.5/.8 2.ninety two/.eight three.53/.eight five./.eight 6.3/.8 seven.5/.8 9.8/.8 12.3/.eight 15.6/.8
.25/1. .36/1. .5/1. .65/1. 1.02/1. 1.4/1. 2./1. 2.7/1. three.2/1. 4.5/1. 5.6/1. 6.8/1. eight.8/1. eleven./1. 14.2/1.
.22/1.three .3/1.3 .forty five/1.three .6/1.3 .86/1.3 1.21/1.three one.8/1.3 2.2/1.3 two.4/1.three three.5/1.3 four.8/1.three 5.8/1.3 seven.2/1.three 9./1.3 eleven.5/1.3
Power/ (Kw) 2.2 three four 5.5 seven.5 eleven 15 eighteen.five 22 thirty 37 forty five fifty five 75 ninety
Ooltage (V/Hz) 380V/50Hz
Sound (±3, dBa) 63 sixty three sixty five 65 67 67 sixty eight 70 seventy two 73 74 seventy five seventy six seventy eight seventy eight
Exhaust temprature Wind cooling type <=Environmental temperature+13ºC, Water cooling type <=40ºC, 
Outlet pipe dimensions one/2″ one/2″ 1/2″ 1/2″ one/2″ three/4″ 1″ 1″ 1″ 1 1/2″ 1 1/2″ 1 1/2″ DN50 DN50 DN50
Fat (Kg) 260 280 three hundred 350 360 four hundred 430 590 650 950 980 1050 1850 1900 2100
Dimensions (mm) 800*760*1102 800*760*1102 800*760*
1102
800*760*
1102
800*760*
1102
950*760*1202 900*one thousand*1290 Belt variety 900*1000*1290 1500*950*1280 1600*1100*1430 1900*1150*1500 2000*1150*1680
Strait sort 1350*850*1257 

 

Product TKL-a hundred and ten
F/W
TKL-132
F/W
TKL-a hundred and sixty
F/W
TKL-185
F/W
TKL-200
F/W
TKL-220
F/W
TKL-250
F/W
TKL-280
F/W
TKL-
315W
TKL-
355W
TKL-
400W
TKL-
450W
TKL-
500W
TKL-
560W
TKL-
630W
Air displacemen/
Exhause strain (m3/min/MPa)
20.4/.seven 24/.7 27.8/.7 32.5/.7 35/.seven forty.7/.seven 45.3/.seven 51.5/.7 fifty seven/.seven sixty eight/.7 73.6/.seven 83/.seven ninety/ten.7 one hundred and one/.7 111/.7
20/.8 23/.8 27.1/.8 thirty.5/.eight 33.3/.8 38.2/.8 43/.eight fifty.5/.eight 55.5/.eight 66.2/.8 71.4/.8 82/.8 89/.eight one hundred/.8 one hundred ten/.eight
seventeen.8/1 21/1. twenty five.2/1. 27/1. 30.6/1. 34.5/1. 38.1/1. forty three/1. fifty.5/1. 55.6/1. 62/1. seventy three/1. 80/1. 86/1. 95/1.
fourteen.5/1.three eighteen.1/1.3 21.2/1.three 23.6/1.three 26.3/1.three 29.8/1.3 35/1.three 38.3/1.3 42.1/1.three 46.5/1.three fifty two.5/1.3 sixty/1.3 68/1.3      
Electricity/ (Kw) a hundred and ten 132 one hundred sixty 185 two hundred 220 250 280 315 355 four hundred 450 five hundred 560 630
Ooltage (V/Hz) 380V/50Hz 380-10000V/50Hz
Sounds (±3, dBa) seventy eight 78 78 78 80 80 80 eighty eighty eighty 82 82 eighty two 82 82
Exhaust temprature Wind cooling type <=Environmental temperature+13ºC, Water cooling type <=40ºC, 
Outlet pipe measurement DN80 DN80 DN80 DN80 DN100 DN100 DN100 DN100 DN125 DN125 DN150 DN150 DN150 DN200 DN200
Fat (Kg) 3300 3500 4000 4600 4700 5100 5100 5500 7500 8300 8400 9000 9500 10000 ten thousand
Dimensions (mm) F 2800*1540*1900 F 2800*1540*1900 F 3150*1650*1900 F 3100*1940*2389 F 3400*2000*2330 4500*200*2462 4650*2340*2835
W 2400*1540*1900 W 2400*1540*1900 W 2600*1700*1980 W 2600*1700*1980 W 3200*1800*2125

Our manufacturing unit and workshop: 

After product sales service for our air screw compressor merchandise: 
1. Providing skilled air compression plan designing for free. 
two. Delivering our manufacturing unit first machine elements at most affordable price soon after machine product sales. 
three. Supplying instruction and guidance for cost-free, clients can ship their personnel to our factory to find out how to function the devices. 
4. Guarantee interval: The screw main equipment is 1 year, the bearing is 1 12 months, the dress in elements of air ingestion valve, electrical components, electromagnetic valve, fee valve are 6 months

Certification and patents of our air compressor

FAQ: 
Q1: Are you manufacturing facility or trade company? 
A1: We are manufacturing unit. 
Q2: Guarantee phrases of your equipment? 
A2: One calendar year guarantee for the device and technical help in accordance to your requirements. 
Q3: Will you provide some spare components of the machines? 
A3: Indeed, of training course. 
This fall: How extended will you just take to set up manufacturing? 
A4: 380V 50Hz we can delivery the products inside of 20 times. Other electrical power or other color we will supply inside of thirty times. 
Q5: Can you settle for OEM orders? 
A5: Sure, with professional design and style team, OEM orders are hugely welcome! 

US $1,000-10,000
/ Set
|
1 Set

(Min. Order)

###

Lubrication Style: Lubricated
Cooling System: Air Cooling
Cylinder Position: Vertical
Structure Type: Closed Type
Installation Type: Stationary Type
Type: Twin-Screw Compressor

###

Customization:

###

Model TKL-2F TKL-3F TKL-4F TKL-5F TKL-7F TKL-11F TKL-15F TKL-18F TKL-22F TKL-30F TKL-37F TKL-45F/W TKL-55F/W TKL-75F/W TKL-90F/W
Air displacement/
Exhause pressure (m3/min/MPa)
0.33/0.7 0.43/0.7 0.6/0.7 0.8/0.7 1.23/0.7 1.65/0.7 2.7/0.7 3.0/0.7 3.6/0.7 5.2/0.7 6.6/0.7 7.8/0.7 10.1/10.7 13.5/0.7 16.3/0.7
0.33/0.8 0.4/0.8 0.55/0.8 0.7/0.8 1.16/0.8 1.62/0.8 2.5/0.8 2.92/0.8 3.53/0.8 5.0/0.8 6.3/0.8 7.5/0.8 9.8/0.8 12.3/0.8 15.6/0.8
0.25/1.0 0.36/1.0 0.5/1.0 0.65/1.0 1.02/1.0 1.4/1.0 2.0/1.0 2.7/1.0 3.2/1.0 4.5/1.0 5.6/1.0 6.8/1.0 8.8/1.0 11.0/1.0 14.2/1.0
0.22/1.3 0.3/1.3 0.45/1.3 0.6/1.3 0.86/1.3 1.21/1.3 1.8/1.3 2.2/1.3 2.4/1.3 3.5/1.3 4.8/1.3 5.8/1.3 7.2/1.3 9.0/1.3 11.5/1.3
Power/ (Kw) 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Ooltage (V/Hz) 380V/50Hz
Noise (±3, dBa) 63 63 65 65 67 67 68 70 72 73 74 75 76 78 78
Exhaust temprature Wind cooling type <=Environmental temperature+13ºC, Water cooling type <=40ºC
Outlet pipe size 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 3/4″ 1″ 1″ 1″ 1 1/2″ 1 1/2″ 1 1/2″ DN50 DN50 DN50
Weight (Kg) 260 280 300 350 360 400 430 590 650 950 980 1050 1850 1900 2100
Dimensions (mm) 800*760*1102 800*760*1102 800*760*
1102
800*760*
1102
800*760*
1102
950*760*1202 900*1000*1290 Belt type 900*1000*1290 1500*950*1280 1600*1100*1430 1900*1150*1500 2000*1150*1680
Strait type 1350*850*1257 

###

Model TKL-110
F/W
TKL-132
F/W
TKL-160
F/W
TKL-185
F/W
TKL-200
F/W
TKL-220
F/W
TKL-250
F/W
TKL-280
F/W
TKL-
315W
TKL-
355W
TKL-
400W
TKL-
450W
TKL-
500W
TKL-
560W
TKL-
630W
Air displacemen/
Exhause pressure (m3/min/MPa)
20.4/0.7 24/0.7 27.8/0.7 32.5/0.7 35/0.7 40.7/0.7 45.3/0.7 51.5/0.7 57/0.7 68/0.7 73.6/0.7 83/0.7 90/10.7 101/0.7 111/0.7
20/0.8 23/0.8 27.1/0.8 30.5/0.8 33.3/0.8 38.2/0.8 43/0.8 50.5/0.8 55.5/0.8 66.2/0.8 71.4/0.8 82/0.8 89/0.8 100/0.8 110/0.8
17.8/1 21/1.0 25.2/1.0 27/1.0 30.6/1.0 34.5/1.0 38.1/1.0 43/1.0 50.5/1.0 55.6/1.0 62/1.0 73/1.0 80/1.0 86/1.0 95/1.0
14.5/1.3 18.1/1.3 21.2/1.3 23.6/1.3 26.3/1.3 29.8/1.3 35/1.3 38.3/1.3 42.1/1.3 46.5/1.3 52.5/1.3 60/1.3 68/1.3      
Power/ (Kw) 110 132 160 185 200 220 250 280 315 355 400 450 500 560 630
Ooltage (V/Hz) 380V/50Hz 380-10000V/50Hz
Noise (±3, dBa) 78 78 78 78 80 80 80 80 80 80 82 82 82 82 82
Exhaust temprature Wind cooling type <=Environmental temperature+13ºC, Water cooling type <=40ºC
Outlet pipe size DN80 DN80 DN80 DN80 DN100 DN100 DN100 DN100 DN125 DN125 DN150 DN150 DN150 DN200 DN200
Weight (Kg) 3300 3500 4000 4600 4700 5100 5100 5500 7500 8300 8400 9000 9500 10000 10000
Dimensions (mm) F 2800*1540*1900 F 2800*1540*1900 F 3150*1650*1900 F 3100*1940*2389 F 3400*2000*2330 4500*200*2462 4650*2340*2835
W 2400*1540*1900 W 2400*1540*1900 W 2600*1700*1980 W 2600*1700*1980 W 3200*1800*2125
US $1,000-10,000
/ Set
|
1 Set

(Min. Order)

###

Lubrication Style: Lubricated
Cooling System: Air Cooling
Cylinder Position: Vertical
Structure Type: Closed Type
Installation Type: Stationary Type
Type: Twin-Screw Compressor

###

Customization:

###

Model TKL-2F TKL-3F TKL-4F TKL-5F TKL-7F TKL-11F TKL-15F TKL-18F TKL-22F TKL-30F TKL-37F TKL-45F/W TKL-55F/W TKL-75F/W TKL-90F/W
Air displacement/
Exhause pressure (m3/min/MPa)
0.33/0.7 0.43/0.7 0.6/0.7 0.8/0.7 1.23/0.7 1.65/0.7 2.7/0.7 3.0/0.7 3.6/0.7 5.2/0.7 6.6/0.7 7.8/0.7 10.1/10.7 13.5/0.7 16.3/0.7
0.33/0.8 0.4/0.8 0.55/0.8 0.7/0.8 1.16/0.8 1.62/0.8 2.5/0.8 2.92/0.8 3.53/0.8 5.0/0.8 6.3/0.8 7.5/0.8 9.8/0.8 12.3/0.8 15.6/0.8
0.25/1.0 0.36/1.0 0.5/1.0 0.65/1.0 1.02/1.0 1.4/1.0 2.0/1.0 2.7/1.0 3.2/1.0 4.5/1.0 5.6/1.0 6.8/1.0 8.8/1.0 11.0/1.0 14.2/1.0
0.22/1.3 0.3/1.3 0.45/1.3 0.6/1.3 0.86/1.3 1.21/1.3 1.8/1.3 2.2/1.3 2.4/1.3 3.5/1.3 4.8/1.3 5.8/1.3 7.2/1.3 9.0/1.3 11.5/1.3
Power/ (Kw) 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Ooltage (V/Hz) 380V/50Hz
Noise (±3, dBa) 63 63 65 65 67 67 68 70 72 73 74 75 76 78 78
Exhaust temprature Wind cooling type <=Environmental temperature+13ºC, Water cooling type <=40ºC
Outlet pipe size 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 3/4″ 1″ 1″ 1″ 1 1/2″ 1 1/2″ 1 1/2″ DN50 DN50 DN50
Weight (Kg) 260 280 300 350 360 400 430 590 650 950 980 1050 1850 1900 2100
Dimensions (mm) 800*760*1102 800*760*1102 800*760*
1102
800*760*
1102
800*760*
1102
950*760*1202 900*1000*1290 Belt type 900*1000*1290 1500*950*1280 1600*1100*1430 1900*1150*1500 2000*1150*1680
Strait type 1350*850*1257 

###

Model TKL-110
F/W
TKL-132
F/W
TKL-160
F/W
TKL-185
F/W
TKL-200
F/W
TKL-220
F/W
TKL-250
F/W
TKL-280
F/W
TKL-
315W
TKL-
355W
TKL-
400W
TKL-
450W
TKL-
500W
TKL-
560W
TKL-
630W
Air displacemen/
Exhause pressure (m3/min/MPa)
20.4/0.7 24/0.7 27.8/0.7 32.5/0.7 35/0.7 40.7/0.7 45.3/0.7 51.5/0.7 57/0.7 68/0.7 73.6/0.7 83/0.7 90/10.7 101/0.7 111/0.7
20/0.8 23/0.8 27.1/0.8 30.5/0.8 33.3/0.8 38.2/0.8 43/0.8 50.5/0.8 55.5/0.8 66.2/0.8 71.4/0.8 82/0.8 89/0.8 100/0.8 110/0.8
17.8/1 21/1.0 25.2/1.0 27/1.0 30.6/1.0 34.5/1.0 38.1/1.0 43/1.0 50.5/1.0 55.6/1.0 62/1.0 73/1.0 80/1.0 86/1.0 95/1.0
14.5/1.3 18.1/1.3 21.2/1.3 23.6/1.3 26.3/1.3 29.8/1.3 35/1.3 38.3/1.3 42.1/1.3 46.5/1.3 52.5/1.3 60/1.3 68/1.3      
Power/ (Kw) 110 132 160 185 200 220 250 280 315 355 400 450 500 560 630
Ooltage (V/Hz) 380V/50Hz 380-10000V/50Hz
Noise (±3, dBa) 78 78 78 78 80 80 80 80 80 80 82 82 82 82 82
Exhaust temprature Wind cooling type <=Environmental temperature+13ºC, Water cooling type <=40ºC
Outlet pipe size DN80 DN80 DN80 DN80 DN100 DN100 DN100 DN100 DN125 DN125 DN150 DN150 DN150 DN200 DN200
Weight (Kg) 3300 3500 4000 4600 4700 5100 5100 5500 7500 8300 8400 9000 9500 10000 10000
Dimensions (mm) F 2800*1540*1900 F 2800*1540*1900 F 3150*1650*1900 F 3100*1940*2389 F 3400*2000*2330 4500*200*2462 4650*2340*2835
W 2400*1540*1900 W 2400*1540*1900 W 2600*1700*1980 W 2600*1700*1980 W 3200*1800*2125

How to Repair and Maintain an Air Compressor

A compressor is a device used to move air from one place to another. Air enters the air compressor through the intake valve. Inside the compressor, the vanes on the inner rotor rotate within an eccentric cavity. The self-adjusting length arm divides the space into multiple cavities of different sizes. As the rotor rotates, air fills the cavity. As air flows around the cavity, it builds pressure and is squeezed out of the compressor output.

Positive displacement

Positive displacement air compressors use reciprocating pistons to compress air. Gas is drawn in during the suction stroke and compressed by moving the piston in the opposite direction. It then discharges the compressed air by moving it in the opposite direction. This type of air compressor is most commonly found in automobiles, refrigerators, and other applications that require high pressure. However, it is not as efficient as a centrifugal compressor.
Most modern air compressors use positive displacement. Positive displacement models capture a volume of air in the compression chamber and distribute it when the pump is operating at maximum capacity. They are more economical than their negative displacement counterparts. Reciprocating screw air compressors are the most common positive displacement compressors. The reciprocating screw air compressor adopts a water jacket around the cylinder and is often used in processes such as oil drilling.
A bicycle pump is an example of positive displacement compression. Air is drawn into the cylinder and compressed by the moving piston. A piston compressor works on the same principle, but it uses a rotating crankshaft or connecting rod to complete the movement of the pistons. There are two types of positive displacement compressors: single-acting and double-acting. Both types work on the same principle, both are positive displacement compressors. The difference between the two types is the pressure ratio.
In air compression, positive displacement compression reduces the volume of the fluid and reduces its viscosity. This results in higher pressure ratios and is used in centrifugal, axial, and scroll compressors. Positive displacement is a common feature of most air compressors. Positive displacement compressors offer the same benefits and are more energy-efficient when applied to oil-free and gas applications. This type of compression is usually the best choice for low-pressure applications.
air-compressor

oil free

If you’re looking for an air compressor for your business, consider an oil-free air compressor. These models offer cleaner, quieter operation than traditional air compressors and require less maintenance. They also meet ISO Class 0 or Class 1 air purity requirements. Oil-free air compressors are also quieter, with fewer moving parts and less noise. These advantages make oil-free air compressors an ideal solution for many commercial applications.
Air purity is critical in many industries. Even the tiniest drop of oil can damage production equipment or damage products. The best way to find an oil-free air compressor for your business is to consider the process and end product. As air quality improves, more and more businesses are turning to oil-free compressors. Some of the advantages and disadvantages of these air compressors are:
When choosing an oil-free air compressor, it is important to understand the terminology used in the industry. Knowing these terms will make it easier for you to choose the right compressor for your needs. ACTFM, or actual cubic feet per minute, is an industry term for measuring the amount of air pumped in one minute under rated conditions. Although a simple number, it can be very useful in determining which type of air compressor is best for your application.
The ISO 8573-1 international standard defines air quality and provides air purity classifications. The strictest classification is air purity class 0. Many manufacturers claim that oil-free air compressors meet this standard. However, a class 0 oil-free air compressor does not necessarily mean that the air is free of contaminants. In fact, Class 0 is the benchmark for air purity. While zero air quality is the highest level, that doesn’t mean it’s completely oil-free.
air-compressor

double acting

A double-acting air compressor is a device that uses compressed air to generate electricity. Its working principle is based on piston and connecting rod. The connecting rod connects the crankshaft to the piston through pins and caps. The piston moves as the piston moves. Rods are usually made of forged carbon steel. In terms of service and maintenance, double-acting compressors require regular vise maintenance and proper cleaning.
The displacement of the compressor is a measure of the displacement that the piston can produce in a certain period of time. Displacement is usually expressed in actual cubic feet per minute. The exact calculation depends on the type of cylinder and the configuration of the compressor. Single-acting cylinders can have head-end or crank-end displacement, both of which can be measured using the displacement equation. A double-acting air compressor will use this equation. 4 and 6 calculate the displacement.
Double-acting air compressors have multiple cylinders and are made of cast iron. They are water-cooled and have a mechanical connection between the piston and connecting rod. A double-acting compressor compresses air twice per revolution of the motor. One cylinder moves up, while the other cylinder moves down. The piston moves down, allowing air to enter through valve #1. During the operation of the compressor, the temperature of the air and gas increases.
Double-acting air compressors typically have high pressure and are considered workhorses. Double-acting compressors also feature intercooling and double compression. As a result, these machines tend to last longer than single-acting compressors. Its low speed and dual compression make it a workhorse in the compressor industry. Double-acting air compressors are workhorses and versatile devices.
air-compressor

fuel tank pressure switch

You can adjust the pressure in the air compressor tank by adjusting the differential pressure. You can turn the mainspring clockwise or counterclockwise to increase or decrease the pressure. This valve will open when the pressure is low enough to start the compressor. If the pressure is too low, the valve should be closed. The cut-in and cut-out pressures should be set to appropriate values. After adjusting the tank pressure, check the hysteresis of the tank pressure switch and set the desired shutoff pressure.
If the pressure in the tank falls below the cut-in level, the tank pressure switch must be replaced. You can test the switch with a multimeter. Make sure the switch is not damaged. If you can’t find the switch, you can look at the other sections. If you find any damaged or missing parts, you should replace them. Otherwise, it may be time to check the tank pressure switch. You may need to disassemble the compressor and remove the switch.
The fuel tank pressure switch is an important part of the air compressor. It keeps you informed of the amount of air delivered by the compressor. If your tank or tank is damaged, your readings will be wrong. If the pressure switch is damaged, it will not function properly and result in incorrect readings. Fortunately, there are some easy ways to fix this. To prevent this from happening, keep the tank pressure switch in good condition.
When the air pressure in the tank drops to the cut-in pressure setting, the switch allows power to flow through it. This will start the motor and pump of the air compressor. Then, if the pressure in the tank rises above the cut-off level, the switch will trip and stop the compressor. This will prevent it from being over-pressurized. Power flow will continue to flow to the motor. Depending on your compressor model, you can change the cut-in and cut-out pressures as needed.

energy source

The power supply of the air compressor is very important. Most air compressors run on 12 VDC, which is ideal for automotive use. Alternatively, you can buy a switching power supply for around $20. No matter which power supply you choose, you must ensure that it can support the maximum current of the compressor. You can find power supplies in all sizes, from quarter-horsepower to five-horsepower.
The voltage required for a three-phase air compressor will vary. Three-phase air compressors require three separate power cords and a three-phase electrical service panel. This is because a standard 120/240-volt electrical service panel is not sufficient to power a three-phase compressor. Additionally, three-phase compressors require three separate isolated wires for the engine and motor circuits. Three-phase compressors do not require a neutral wire.

China Electric Oil Lubricated Rotary Screw Air Compressor     portable air compressorChina Electric Oil Lubricated Rotary Screw Air Compressor     portable air compressor
editor by czh 2023-01-07