Solution Description

 

Fully optimized screw air compressor system to reduce force decline&semi Making use of the business-major host and valve engineering of Ganey&semi External air suction to boost the performance&semi Extending the energy preserving, reliable and quiet merchandise attributes of Ganey.
one. Airend with CZPT 3-line meshing sophisticated engineering to get China, United states of america, Japan, British and French Patent.
two. First essential factors are imported.
three. Minimal Engergy Consumption, reduced runing, servicing expense.
four. Aptitude and clever Handle, PLC management, Lcd displayer.
five. Effortless to put in, function, maintent.

Model OG&lparF)D-6.4&sol7 OG&lparF)D-6.1&sol8 OG&lparF)D-5.3&sol10 OG&lparF)D-4.7&sol12.5
Capacity&solPressure 6.4&sol0.seven 6.1&sol0.8 5.3&sol1. 4.7&sol1.twenty five
&lparm3&solmin.Mpa-1)
 
Motor Electrical power&lparKW) 37KW&lpar50HP)
Speed&lparr&solmin) 2950
Starting up way Direct Relationship, Y-Triangle Lower-voltage Startup
Volt&lparV) 380 &lpar440&sol220)
Motor basic safety grade IP54
Motor isolation quality F
Electrical Source 380V&sol50Hz&sol3Phase  or 440&lpar220)V&sol60Hz&sol3Phase
Air-supply Temperature &lpar°C) ≤Enviroment Temperature&pm 15ºC
Driven way Direct Pushed
Noise level at 1 meter 68&pm3dB&lparA)
Cooled technique Air cooling
Oil material ≤3 ppm
Outlet Relationship G 1-1&sol4″
Dimension Length&lparmm) 1620
Width&lparmm) 860
Peak&lparmm) 1250
Weight&lparkg) 800

 

Product

Device SMC-03A SMC-05A SMC -08A SMC-10A SMC-15A SMC-20A SMC-25A SMC-30A SMC-40A SMC-50A
Cooling Ability WATTS 8250 11324 20540 28400 43100 58600 69700 86200 117200 139400
BTU&solHR 29000 38650 77300 97000 147200 199850 237700 294400 399700 476000
KCAL&solHR 7308 9740 19480 24444 37094 50362 59900 74189 10571 119952
Refrigerant Variety R22
Compressor Motor KW 2.two 3.three 6 7.5 11.25 15 eighteen.five 22.five thirty 37.five
HP 3HP 4.5 8 ten 15 twenty 25 30 40 50
Condenser Supporter Circulation Fee&lparA) CHM 2390 3900 7800 9200 12600 18900 18900 23400 31200 39000
Enthusiast DiaΦ MM 300&ast2 400&ast2 450&ast2 500&ast2 500&ast3 550&ast3 Φ 600&ast3 Φ 630&ast3 Φ 500&ast6 Φ five hundred&ast8
Fan Power WATTS 74W&ast2 145W&ast2 273W&ast2 273W&ast2 382W&ast3 614W&ast3 708W&ast3 795W&ast3 708W&ast6 708W&ast6
H2o Tank potential LITER sixty five sixty five 140 220 380 500 five hundred 520 630 800
Water Pump HP   1&sol2   1&sol2 one one 2 2 3 five 7.5 7.five
KW .37 .37 .seventy five .75 one.five 1.5 2.two three.75 5.62 5.62
Flow Charge L&solMIN 50-100 fifty-one hundred a hundred-two hundred a hundred-two hundred one hundred sixty-320 one hundred sixty-320 250-five hundred four hundred-800 630-1200 630-1200
  Working Existing AMP six nine thirteen 15 27 38 forty five 58 75 95
Insulation Materials POLY-FOAM TAPE RUBBERIZED TUBU INSULATION
Dimension L&astW&astH MM 1100&ast615&ast1080 1100&ast615&ast1080 1380&ast750&ast1450 1480&ast750&ast1450 1700&ast1100&ast1750 1800&ast1100&ast1750 1830&ast860&ast1900 1980&ast860&ast1950 2300&ast1800&ast1980 2550&ast1800&ast2100
Net Fat KG 155 155 320 420 600 730 780 920 1050 1100

 

Model

Motor Conveying Capa.&lparkg&solhr) Feed Capa.&lparL) Pipe diameter&lparmm) External dimensions&lparmm) Weight&lparkg)
Kind Specs Entire body Hopper Entire body Hopper
RAL-300I Carbon brush 1000w three hundred 6 Dia.38 550&ast350&ast250 12
RAL-403I Induction 1HP 400 10 Dia.38 800&ast450&ast450 25

US $30,000-40,000
/ Piece
|
1 Piece

(Min. Order)

###

Screw: Non-Screw
Computerized: Computerized
Machine Specification: 800*420*850 mm
Transport Packaging: Film and Wooden Cases
Certification: SGS
Transport Package: Film Packing

###

Customization:

###

Model OG(F)D-6.4/7 OG(F)D-6.1/8 OG(F)D-5.3/10 OG(F)D-4.7/12.5
Capacity/Pressure 6.4/0.7 6.1/0.8 5.3/1.0 4.7/1.25
(m3/min.Mpa-1)
 
Motor Power(KW) 37KW(50HP)
Speed(r/min) 2950
Starting way Direct Connection, Y-Triangle Low-voltage Startup
Volt(V) 380 (440/220)
Motor safety grade IP54
Motor isolation grade F
Electrical Supply 380V/50Hz/3Phase  or 440(220)V/60Hz/3Phase
Air-supply Temperature (°C) ≤Enviroment Temperature± 15ºC
Driven way Direct Driven
Noise level at 1 meter 68±3dB(A)
Cooled method Air cooling
Oil content ≤3 ppm
Outlet Connection G 1-1/4"
Dimension Length(mm) 1620
Width(mm) 860
Height(mm) 1250
Weight(kg) 800

###

MODEL

UNIT SMC-03A SMC-05A SMC -08A SMC-10A SMC-15A SMC-20A SMC-25A SMC-30A SMC-40A SMC-50A
Cooling Capacity WATTS 8250 11324 20540 28400 43100 58600 69700 86200 117200 139400
BTU/HR 29000 38650 77300 97000 147200 199850 237700 294400 399700 476000
KCAL/HR 7308 9740 19480 24444 37094 50362 59900 74189 100724 119952
Refrigerant Type R22
Compressor Motor KW 2.2 3.3 6 7.5 11.25 15 18.5 22.5 30 37.5
HP 3HP 4.5 8 10 15 20 25 30 40 50
Condenser Fan Flow Rate(A) CHM 2390 3900 7800 9200 12600 18900 18900 23400 31200 39000
Fan DiaΦ MM 300*2 400*2 450*2 500*2 500*3 550*3 Φ 600*3 Φ 630*3 Φ 500*6 Φ 500*8
Fan Power WATTS 74W*2 145W*2 273W*2 273W*2 382W*3 614W*3 708W*3 795W*3 708W*6 708W*6
Water Tank capacity LITER 65 65 140 220 380 500 500 520 630 800
Water Pump HP   1/2   1/2 1 1 2 2 3 5 7.5 7.5
KW 0.37 0.37 0.75 0.75 1.5 1.5 2.2 3.75 5.62 5.62
Flow Rate L/MIN 50-100 50-100 100-200 100-200 160-320 160-320 250-500 400-800 630-1200 630-1200
  Running Current AMP 6 9 13 15 27 38 45 58 75 95
Insulation Material POLY-FOAM TAPE RUBBERIZED TUBU INSULATION
Dimension L*W*H MM 1100*615*1080 1100*615*1080 1380*750*1450 1480*750*1450 1700*1100*1750 1800*1100*1750 1830*860*1900 1980*860*1950 2300*1800*1980 2550*1800*2100
Net Weight KG 155 155 320 420 600 730 780 920 1050 1100

###

Model

Motor Conveying Capa.(kg/hr) Feed Capa.(L) Pipe diameter(mm) External size(mm) Weight(kg)
Type Specs Body Hopper Body Hopper
RAL-300I Carbon brush 1000w 300 6 Dia.38 550*350*250 12
RAL-403I Induction 1HP 400 10 Dia.38 800*450*450 25
US $30,000-40,000
/ Piece
|
1 Piece

(Min. Order)

###

Screw: Non-Screw
Computerized: Computerized
Machine Specification: 800*420*850 mm
Transport Packaging: Film and Wooden Cases
Certification: SGS
Transport Package: Film Packing

###

Customization:

###

Model OG(F)D-6.4/7 OG(F)D-6.1/8 OG(F)D-5.3/10 OG(F)D-4.7/12.5
Capacity/Pressure 6.4/0.7 6.1/0.8 5.3/1.0 4.7/1.25
(m3/min.Mpa-1)
 
Motor Power(KW) 37KW(50HP)
Speed(r/min) 2950
Starting way Direct Connection, Y-Triangle Low-voltage Startup
Volt(V) 380 (440/220)
Motor safety grade IP54
Motor isolation grade F
Electrical Supply 380V/50Hz/3Phase  or 440(220)V/60Hz/3Phase
Air-supply Temperature (°C) ≤Enviroment Temperature± 15ºC
Driven way Direct Driven
Noise level at 1 meter 68±3dB(A)
Cooled method Air cooling
Oil content ≤3 ppm
Outlet Connection G 1-1/4"
Dimension Length(mm) 1620
Width(mm) 860
Height(mm) 1250
Weight(kg) 800

###

MODEL

UNIT SMC-03A SMC-05A SMC -08A SMC-10A SMC-15A SMC-20A SMC-25A SMC-30A SMC-40A SMC-50A
Cooling Capacity WATTS 8250 11324 20540 28400 43100 58600 69700 86200 117200 139400
BTU/HR 29000 38650 77300 97000 147200 199850 237700 294400 399700 476000
KCAL/HR 7308 9740 19480 24444 37094 50362 59900 74189 100724 119952
Refrigerant Type R22
Compressor Motor KW 2.2 3.3 6 7.5 11.25 15 18.5 22.5 30 37.5
HP 3HP 4.5 8 10 15 20 25 30 40 50
Condenser Fan Flow Rate(A) CHM 2390 3900 7800 9200 12600 18900 18900 23400 31200 39000
Fan DiaΦ MM 300*2 400*2 450*2 500*2 500*3 550*3 Φ 600*3 Φ 630*3 Φ 500*6 Φ 500*8
Fan Power WATTS 74W*2 145W*2 273W*2 273W*2 382W*3 614W*3 708W*3 795W*3 708W*6 708W*6
Water Tank capacity LITER 65 65 140 220 380 500 500 520 630 800
Water Pump HP   1/2   1/2 1 1 2 2 3 5 7.5 7.5
KW 0.37 0.37 0.75 0.75 1.5 1.5 2.2 3.75 5.62 5.62
Flow Rate L/MIN 50-100 50-100 100-200 100-200 160-320 160-320 250-500 400-800 630-1200 630-1200
  Running Current AMP 6 9 13 15 27 38 45 58 75 95
Insulation Material POLY-FOAM TAPE RUBBERIZED TUBU INSULATION
Dimension L*W*H MM 1100*615*1080 1100*615*1080 1380*750*1450 1480*750*1450 1700*1100*1750 1800*1100*1750 1830*860*1900 1980*860*1950 2300*1800*1980 2550*1800*2100
Net Weight KG 155 155 320 420 600 730 780 920 1050 1100

###

Model

Motor Conveying Capa.(kg/hr) Feed Capa.(L) Pipe diameter(mm) External size(mm) Weight(kg)
Type Specs Body Hopper Body Hopper
RAL-300I Carbon brush 1000w 300 6 Dia.38 550*350*250 12
RAL-403I Induction 1HP 400 10 Dia.38 800*450*450 25

How to Repair and Maintain an Air Compressor

A compressor is a device used to move air from one place to another. Air enters the air compressor through the intake valve. Inside the compressor, the vanes on the inner rotor rotate within an eccentric cavity. The self-adjusting length arm divides the space into multiple cavities of different sizes. As the rotor rotates, air fills the cavity. As air flows around the cavity, it builds pressure and is squeezed out of the compressor output.

Positive displacement

Positive displacement air compressors use reciprocating pistons to compress air. Gas is drawn in during the suction stroke and compressed by moving the piston in the opposite direction. It then discharges the compressed air by moving it in the opposite direction. This type of air compressor is most commonly found in automobiles, refrigerators, and other applications that require high pressure. However, it is not as efficient as a centrifugal compressor.
Most modern air compressors use positive displacement. Positive displacement models capture a volume of air in the compression chamber and distribute it when the pump is operating at maximum capacity. They are more economical than their negative displacement counterparts. Reciprocating screw air compressors are the most common positive displacement compressors. The reciprocating screw air compressor adopts a water jacket around the cylinder and is often used in processes such as oil drilling.
A bicycle pump is an example of positive displacement compression. Air is drawn into the cylinder and compressed by the moving piston. A piston compressor works on the same principle, but it uses a rotating crankshaft or connecting rod to complete the movement of the pistons. There are two types of positive displacement compressors: single-acting and double-acting. Both types work on the same principle, both are positive displacement compressors. The difference between the two types is the pressure ratio.
In air compression, positive displacement compression reduces the volume of the fluid and reduces its viscosity. This results in higher pressure ratios and is used in centrifugal, axial, and scroll compressors. Positive displacement is a common feature of most air compressors. Positive displacement compressors offer the same benefits and are more energy-efficient when applied to oil-free and gas applications. This type of compression is usually the best choice for low-pressure applications.
air-compressor

oil free

If you’re looking for an air compressor for your business, consider an oil-free air compressor. These models offer cleaner, quieter operation than traditional air compressors and require less maintenance. They also meet ISO Class 0 or Class 1 air purity requirements. Oil-free air compressors are also quieter, with fewer moving parts and less noise. These advantages make oil-free air compressors an ideal solution for many commercial applications.
Air purity is critical in many industries. Even the tiniest drop of oil can damage production equipment or damage products. The best way to find an oil-free air compressor for your business is to consider the process and end product. As air quality improves, more and more businesses are turning to oil-free compressors. Some of the advantages and disadvantages of these air compressors are:
When choosing an oil-free air compressor, it is important to understand the terminology used in the industry. Knowing these terms will make it easier for you to choose the right compressor for your needs. ACTFM, or actual cubic feet per minute, is an industry term for measuring the amount of air pumped in one minute under rated conditions. Although a simple number, it can be very useful in determining which type of air compressor is best for your application.
The ISO 8573-1 international standard defines air quality and provides air purity classifications. The strictest classification is air purity class 0. Many manufacturers claim that oil-free air compressors meet this standard. However, a class 0 oil-free air compressor does not necessarily mean that the air is free of contaminants. In fact, Class 0 is the benchmark for air purity. While zero air quality is the highest level, that doesn’t mean it’s completely oil-free.
air-compressor

double acting

A double-acting air compressor is a device that uses compressed air to generate electricity. Its working principle is based on piston and connecting rod. The connecting rod connects the crankshaft to the piston through pins and caps. The piston moves as the piston moves. Rods are usually made of forged carbon steel. In terms of service and maintenance, double-acting compressors require regular vise maintenance and proper cleaning.
The displacement of the compressor is a measure of the displacement that the piston can produce in a certain period of time. Displacement is usually expressed in actual cubic feet per minute. The exact calculation depends on the type of cylinder and the configuration of the compressor. Single-acting cylinders can have head-end or crank-end displacement, both of which can be measured using the displacement equation. A double-acting air compressor will use this equation. 4 and 6 calculate the displacement.
Double-acting air compressors have multiple cylinders and are made of cast iron. They are water-cooled and have a mechanical connection between the piston and connecting rod. A double-acting compressor compresses air twice per revolution of the motor. One cylinder moves up, while the other cylinder moves down. The piston moves down, allowing air to enter through valve #1. During the operation of the compressor, the temperature of the air and gas increases.
Double-acting air compressors typically have high pressure and are considered workhorses. Double-acting compressors also feature intercooling and double compression. As a result, these machines tend to last longer than single-acting compressors. Its low speed and dual compression make it a workhorse in the compressor industry. Double-acting air compressors are workhorses and versatile devices.
air-compressor

fuel tank pressure switch

You can adjust the pressure in the air compressor tank by adjusting the differential pressure. You can turn the mainspring clockwise or counterclockwise to increase or decrease the pressure. This valve will open when the pressure is low enough to start the compressor. If the pressure is too low, the valve should be closed. The cut-in and cut-out pressures should be set to appropriate values. After adjusting the tank pressure, check the hysteresis of the tank pressure switch and set the desired shutoff pressure.
If the pressure in the tank falls below the cut-in level, the tank pressure switch must be replaced. You can test the switch with a multimeter. Make sure the switch is not damaged. If you can’t find the switch, you can look at the other sections. If you find any damaged or missing parts, you should replace them. Otherwise, it may be time to check the tank pressure switch. You may need to disassemble the compressor and remove the switch.
The fuel tank pressure switch is an important part of the air compressor. It keeps you informed of the amount of air delivered by the compressor. If your tank or tank is damaged, your readings will be wrong. If the pressure switch is damaged, it will not function properly and result in incorrect readings. Fortunately, there are some easy ways to fix this. To prevent this from happening, keep the tank pressure switch in good condition.
When the air pressure in the tank drops to the cut-in pressure setting, the switch allows power to flow through it. This will start the motor and pump of the air compressor. Then, if the pressure in the tank rises above the cut-off level, the switch will trip and stop the compressor. This will prevent it from being over-pressurized. Power flow will continue to flow to the motor. Depending on your compressor model, you can change the cut-in and cut-out pressures as needed.

energy source

The power supply of the air compressor is very important. Most air compressors run on 12 VDC, which is ideal for automotive use. Alternatively, you can buy a switching power supply for around $20. No matter which power supply you choose, you must ensure that it can support the maximum current of the compressor. You can find power supplies in all sizes, from quarter-horsepower to five-horsepower.
The voltage required for a three-phase air compressor will vary. Three-phase air compressors require three separate power cords and a three-phase electrical service panel. This is because a standard 120/240-volt electrical service panel is not sufficient to power a three-phase compressor. Additionally, three-phase compressors require three separate isolated wires for the engine and motor circuits. Three-phase compressors do not require a neutral wire.

China Energy Saving Screw Air Compressor     air compressor priceChina Energy Saving Screw Air Compressor     air compressor price
editor by czh 2023-01-24